Global Soul Limited

Use our work to create value for customers

Manufacturer from China
Verified Supplier
1 Years
Home / Products / SMT Machine Spare Parts /

Reflow Oxygen Analyzer WZ-200D Oxygen Content Analyzer SMT Analyzer

Contact Now
Global Soul Limited
Visit Website
City:shenzhen
Country/Region:china
Contact Person:MrYi Lee
Contact Now

Reflow Oxygen Analyzer WZ-200D Oxygen Content Analyzer SMT Analyzer

Ask Latest Price
Video Channel
Brand Name :TX
Model Number :WZ-200D
Place of Origin :China
MOQ :1 PCS
Price :USD+negotiable+pcs
Payment Terms :T/T
Supply Ability :1+pcs+per days
Delivery Time :1-7 days
Packaging Details :358mmx230mmx400mm(WxHxD)
Product Name :SMT analyzer
Condition :Original New/Used Original
more
Contact Now

Add to Cart

Find Similar Videos
View Product Description

• Product Features:
Imported double zirconia sensor, high measurement accuracy, fast response, calibration
Long cycle and other characteristics;
It can work in the air for a long time without affecting the life of the sensor;
Fast response speed, the lowest measurement 1ppm;
Wide range AC power supply, wider application range;
Any point calibration can meet the measurement accuracy of the entire range, making the calibration simple and convenient: built-in temperature automatic compensation function, reduce the impact of temperature changes on the measurement accuracy: no reference gas, not affected by the oxygen concentration of the working environment;
Friendly man-machine dialogue menu, intuitive and convenient operation;
Can be one-way or two-way communication with the host computer;
Built-in original imported sampling pump, and through the software can set the working mode of the pump.

Technical parameters:
Measurement principle: Zirconia
Display mode :128x64 dot matrix LCD
Measuring range :0~10/100/1000ppm/1.00%/25.00%0
Resolution :1ppm
Permissible error: 0-1000 parts per million (PPM) 1% / 1.00% / 10.00% / 25.00% plus or minus F.S 0-100 parts per million (PPM) + 2% or less F.S 0 to 10 PPM F.S plus or minus 5%
Repeatability :≤±1%
Response time :T≤30S
Analog output :4-20mA.DC(non-isolated output, load resistance less than 500 ohms)0~10V.DC(non-isolated output, load resistance greater than 10 kiloohms)1 programmable dry contact type passive alarm output, contact maximum capacity 220VAC/2A
Other interfaces :RS232(default) or RS485 Power supply :AC85-264V50/60HZ
Sample temperature :-10~+50℃
Sample gas flow rate :400-600ml/min
Sampling method: Extraction type, ejection type or ejection style Gas pressure: micro positive pressure, micro negative pressure or normal pressure background gas :N, and inert gas and other mixed gases
Size :258mmx130mmx300mm(WxHxD)
Opening size :238mmx132mm(WxH)
Service life :>12 months (under normal operating conditions)
Gas connection :NPT 1/8 internal thread
Installation mode: embedded installation

Reflow Oxygen Analyzer WZ-200D Oxygen Content Analyzer SMT Analyzer

Inquiry Cart 0