Mid-Range Profile Setter
1.The K2 profile setter replaces the last of KIC′s older technology profilers
2.Competitively priced for the mid-range market.
Compact and Robust Hardware
The K2 will fit through the tight heated chambers often found in lead-free production
7 TC unit dimensions: 206 x 60 x 17(mm)
Shield: 302 x 75 x 23(mm)
9 TC unit dimensions: 206 x 75 x 17(mm)
Shield: 312 x 90 x 23(mm)
Durable hardware designed to withstand rough production environments
Fail-Safe Operation
1. Automatic start when temperatures are below a specified ′start′ trigger,protecting the K2 and assuring consistent starting
points and repeatable profiles.
2.Hardware designed for accurate measurements.
3.Engineer sets quality and productivity related parameters:
√PWl level
√Minimum/maximum allowable conveyor speed
√Maximum peak temperature, etc.
4.For use by operators, technicians and engineers
Oven Setup Software
1. KIC's optimization software does acomplete search for all possible combinations of oven zone temperatures and conveyor speeds.lt selects the very best oven setup for each new product within seconds
2. User selectable setup criteria focuses on positioning the profile towards:
√ the center of the process window
√ maximum conveyor speed
√ minimum oven electricity usage
Instant and Objective Profile Analysis
1. KIC's famous Process Window Index(PWI) explains how the profile fits the established process window, with a single number:
√ PWl above 100 = profile out of spec
√ PWl at 100= profile right on the spec limit
√ PWI below 100 = profile in spec
√ PWl at 0 = the exact center of the process window
2. lmmediate profile analysis
3. Objective and personnel-independent profile analysis
4. Outlying profile data made visible
Accessing the K2 Profile Data on the PC or Mobile Device
1.The profile data can be displayed in two ways:
√ On the oven PC or profiling PC
√ On an Authorized Android mobile device
2. Convenient sharing function for selectedprofile data